Ul 752 standard download

Standards since 1901, ul has been creating standards for product safety. Table 63 thickness of common materials for resistance against ul 752 level v. Underwriters laboratory ul 752 ballistic standards standard. Dlubak corporations bullet resistant laminates offer a complete line of ul listed nospall ballistic protection.

Bullet resistant glass ul 752 impactresistant glass. The current and updated guide spec for armorcore is listed under the 2011 edition below which identifies the placement of bullet resistant panels in section 10. Bulletproof glass ballistic glass, transparent armor, and bulletresistant glass is a strong and optically transparent material that is particularly resistant to penetration by projectiles. With over 1,000 standards available for delivery in hardcopy, pdf, or electronic html formats, if youre looking for a ul standard youve come to the right place. Ratings of bullet resistant materials as identified by ul 752. Available in all ul 752 ratings, armorcore panels encapture ballistic. Ul 752 level 3 super power hand guns bullet resistant. Ideal utility services ul 752 standard ballistic levels chart. If a ballisticresistant product is tested to ul standards, but is not certified, there is a risk it may fail to perform as it did during original testing. Waco composites can provide current certificates of compliance upon request.

Human sumo2 shares 44% and 86% identity with sumo1 and sumo3 respectively. Our breadth, established objectivity and proven history mean we are a symbol of trust, enabling us to help provide peace of mind to all. Optional construction for ul 762 restaurant exhaust. Functional safety is the part of overall safety that depends on the correct functioning of safetyrelated control systems and software. Available in flat panels for insequence installation safecorridor dividers. Bullet resisting equipment for materials, devices and fixtures. All products conform with ul 752 standard for safety for bullet resisting equipment. Indoor ul 752 standard for bullet resisting equipment.

Bulletresistant glazing for motor vehicles operating on land highways is available in various levels of resistance as specified in ansi ul 752 2005, standard for bulletresisting equipment, levels 1 through 8 and supplementary shotgun. With ul 752 standard and level 3,4,7, 8 and 10 ballistic testing, ideals ballistic barriers will help protect and secure critical assets from long range and close range ballistic attacks, as well as several other forms of attack. Like any other material, it is not completely impenetrable. Ul 752standard for bullet resisting equipment ansibhma a156. Ballistic laminated glass is a material that is constructed from a combination of standard or low iron glass and polycarbonate or pvb interlayer materials. Provides protection against five shots of a 124grain 9mm full metal copper jacket with lead core at an fps between 1400 and 1540. Councils of standards australia new zealand asnz 2343. The ubiquitinlike sumo2 is conjugated to a variety of proteins in the presence of ube2i ubc9 and the sae1sae2 human or aos1uba2 yeast activating enzyme. American national standard for safety glazing materials.

Underwriters laboratory ul 752 certification standard for bulletresisting equipment protection for military, diplomatic, institutional and corporate high security facilities. View and download greenheck ul 762 features online. Home united facilities criteria cd 2 table 62 thickness of common materials for resistance against ul 752 level iii. Manufacturers may find it beneficial to obtain an intertek certification etl mark to provide thirdparty assurance of their materials performance characteristics. This is unlike many other product categories covered by ul standard which normally concentrate on electric shock and fire hazards only. Cd 2 table 62 thickness of common materials for resistance against ul 752. Ansi ul 752, standard for safety bulletresistant equipment, 2005, revised20072010. Underwriters laboratory ul752 ballistic standards close. Ul standards purchase ul standards online ul standards.

When ordering products, please specify the required level of ballistic protection. Bullet resistant doors a range of fully tested and certified ballistic single and double doors. We also offer two different types of subscriptions. Ul as being bullet resisting assemblies in compliance with standard for safetyul 752, bulletresisting equipment for the following threat levels.

Ul 752 specification for secureall bullet resistant. Ul 752 protection standards for bullet resistant glass products. Subsequently, one of the raw materials used in the. Bullet resistant glass dlubak specialty glass corporation. Examples of this leadership are highlighted by the firstever stationary battery standard ansican ul 1973, the worlds first energy storage system standard ansican ul 9540 as well as recent publication of the ul 9540a test method. Units have been designed to accept readily available heavyweight builders hardware. Ul 681 standard for installation and classification of burglar and holdup alarm systems, 1999, revised 2001. Ul 752 standard ballistic levels chart ideal utility. Light emitting diode led equipment for use in lighting. Cut armortex opaque fiberglass using ordinary carpentry tools. What is the bulletballistic resistance of concrete masonry. The data shown below for ul752 test standards does not contain all the information required for each test level. For more information on the ul752 standard and to download the pdf, please click the link. Security glass bullet resistant ul 752 listed bullet resistant laminates offer a complete line of ul 752 listed nospall ballistic protection.

The ul 752 ratings offer a system for understanding ballistic protection in bullet resistant glass. Underwriters laboratory ul 752 certification standard for bulletresisting equipment. Ratings of bullet resistant materials as identified by. Download the latest armorcore specs, testing docs and cut sheets.

Bulletresisting equipment for materials, devices and fixtures. Per ul 752, this test method is conducted to determine whether protection is provided against complete penetration, passage of fragments of. Readonly copies of those standards are available to the public at the ul website the following ul standards are available in paper copy in the noble library on the tempe campus. Mar 18, 2016 if a ballisticresistant product is tested to ul standards, but is not certified, there is a risk it may fail to perform as it did during original testing. It outlines a test protocol for common small arms threats ranging from shotguns to handguns to small caliber rifles. The official ul 752 testing procedure requires multiple identical samples tested to the same level including parts 1, 2, and 3 if applicable. Data was intentionally left out to provide the basic information about the standard.

Distribution without permission from ul ul standard for safety for light emitting diode led equipment for use in lighting products, ul 8750 first edition, dated november 18, 2009 summary of topics this first edition of the standard for light emitting diode led equipment for use in lighting. Underwriters laboratory ul 752 ballistic standards the data shown below for ul752 test standards does not contain all the information required for each test level. Some ul standards are ibr incorporated by reference into the us code of federal regulations. Patented design, 510 day lead time on standard windows. Ul 752 specifications and ammunition minimum velocity rating ammunition grain g fps ms shots fired paragraph level 1 9 mm full metal copper jacket with lead core 124 8 1175 358 3 4. Underwriters laboratory ul 752 ballistic standards standard rating. The data shown below for ul752 test standards does not contain all the information required for each test. Ul standards encompass ul s extensive safety research and scientific expertise. Assemblies are listed by underwriters laboratories,inc. For example, a ballisticresistant product is tested at a lab and passes the ul 752, standard for bulletresisting equipment examinations. Face veneers are available in a wide variety of paint grade or stain grade options. The most common ballistic standards are ul 752 and the national institute of justice nij. Ul 746c ul standard for safety polymeric materials use in electrical equipment evaluations published by ul on february 5, 2018 these requirements cover parts made of polymeric materials that are used in electrical equipment and describe the various test procedures and their use in the testing of such parts and equipment.

Provides protection against five shots of a 55grain 5. Ul 752 standard for bulletresisting equipment it is important to determine ul listed products and not just compliant materials. Ul 752 standard for bulletresisting equipment standards. Ballistic rating charts for ul752 and nij nationwide structures, inc. Table 62 thickness of common materials for resistance. American national standard for safety glazing materials for. Bulletstop is a bullet resistant sectional door for your maximum security applications. Underwriters laboratory ul752 ballistic standards close focus.

With over a century of experience in the development of more than 1,500 standards, ul is an accredited standards developer in the us and canada. For submittals, to learn more, or to inquire about related continuing. Add ansi approval designation to ansi ul 752 and update to most recent edition. When printing, be sure to print in landscape mode for best results. For assemblies and special circumstances, the sample size may vary. Ul 2054 ul standard for safety household and commercial. Ul 972 ul standard for safety burglary resisting glazing. Ul 752 protection standards for bullet resistant glass. Ul 752 standard for bulletresisting equipment standards catalog.

Ul 752 is the most common ballistic specification written by underwriters laboratory. Ul 752 standard for bulletresisting equipment this standard is a us standard, from the underwriters laboratories. This standard evaluates the system based upon the manufacturers specified charge and discharge parameters. Ul 1741 is a unique standard performance issues associated with the grid interactive operation of the dg groducts are important safety issues. Nfpa technical committee on public emergency services communication. Intertek offer testing and certification services for standard ul 752. Most commonly used protection against hand guns of super power, such as the. Ul 1076 ul standard for safety proprietary burglar alarm units and systems published by ul on april 6, 2018 these requirements apply to the construction, performance and operation of equipment intended for use in proprietary burglar alarm units and systems used to protect against burglary. Underwriters laboratory ul 752 ballistic standards.

Ul 1973 standard for batteries for use in stationary. Insulgard products are rated for levels of protection through engineering and testing in laboratory conditions to meet standards ul 752 level 110. Back to standard 752, edition 11 the cost to purchase this standard varies depending on whether you are ordering a hardcopy, pdf or combination of the two. Recent testing by a us federal agency of ace security laminates. The standard covers materials, devices, and fixtures used to form bulletresisting barriers which protect against robbery, holdup or armed attack such as those by snipers. Table 62 thickness of common materials for resistance against ul 752 level iii. Laminates or homogeneous glazing materials that meet the appropriate requirements of this standard in the location as specified may be used as bulletresistant glazing for the foregoing. Bullet resistant products ballistic safety products. Although the firearms and bullets used in this study dont match underwriters laboratories ul 752 standard for bulletresisting equipmentbullet level classifications 18 the standard often cited for bullet resistance, a comparison can be made. Testing ul 752 levels 110 insulgard security products.

Rating ammunition weight grains weight grams minimum fps maximum fps number of shots. Ul is a global independent safety science company offering expertise across three strategic businesses. Control panel technical guide how to ensure troublefree approval of your ul compliant control panels 6 1 ul standards and control panel design definition of electrical circuits as per standard ul 508a chap. Ul 762 outline of investigation for power roof ventilators. Waco composites can provide current certificates of.